Standard Model LPC 11845 Series
Signal, Wire, Communications, and Data Surge Protective Devices
Wire pair protection, in-line installation, screw terminals. In-line impedance 10 ohms. For signal voltages 5 to 170V peak (AC and DC). Bipolar operation, instantaneous and automatic. Line terminals carry the surges, equipment terminals are protected. Mounting legs connected to ground. Surge current rating 15,000 amperes for 8/20 µs and 750 amperes on 10/1000 µs wave.
Model P/N |
Max Signal (volts peak) |
Beginning Clamp V (volts peak) |
---|---|---|
LPC 11845-5 LPC 11845-5/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 5 | Beginning Clamp V (volts peak) N/A 6 |
LPC 11845-10 LPC 11845-10/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 10 | Beginning Clamp V (volts peak) N/A 12 |
LPC 11845-15 LPC 11845-15/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 15 | Beginning Clamp V (volts peak) N/A 18 |
LPC 11845-20 LPC 11845-20/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 20 | Beginning Clamp V (volts peak) N/A 22 |
LPC 11845-25 LPC 11845-25/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 25 | Beginning Clamp V (volts peak) N/A 30 |
LPC 11845-30 LPC 11845-30/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 30 | Beginning Clamp V (volts peak) N/A 35 |
LPC 11845-35 LPC 11845-35/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 35 | Beginning Clamp V (volts peak) N/A 42 |
LPC 11845-40 LPC 11845-40/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 40 | Beginning Clamp V (volts peak) N/A 45 |
LPC 11845-45 LPC 11845-45/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 45 | Beginning Clamp V (volts peak) N/A 50 |
LPC 11845-50 LPC 11845-50/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 50 | Beginning Clamp V (volts peak) N/A 56 |
LPC 11845-60 LPC 11845-60/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 60 | Beginning Clamp V (volts peak) N/A 64 |
LPC 11845-65 LPC 11845-65/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 65 | Beginning Clamp V (volts peak) N/A 70 |
LPC 11845-75 LPC 11845-75/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 75 | Beginning Clamp V (volts peak) N/A 82 |
LPC 11845-85 LPC 11845-85/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 85 | Beginning Clamp V (volts peak) N/A 92 |
LPC 11845-100 LPC 11845-100/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 100 | Beginning Clamp V (volts peak) N/A 110 |
LPC 11845-120 LPC 11845-120/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 120 | Beginning Clamp V (volts peak) N/A 130 |
LPC 11845-145 LPC 11845-145/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 145 | Beginning Clamp V (volts peak) N/A 155 |
LPC 11845-170 LPC 11845-170/Asset/LPC-11845.jpg | Max Signal (volts peak) N/A 170 | Beginning Clamp V (volts peak) N/A 180 |